Life Ionizers is Your Commercial Ionization Solution

Life CE 2000 Commercial Unit

Submit a Request for More Information

We Offer 4 Commercial Units, Information Aavailable Below

If you would like to speak with a commercial unit specialist, please call now at 877-959-7977.

Commercial Application:

Commercial usage with the capability of producing 1,000 – 4,000 liters per hour. Some common applications include: water bottlers, dairy, beef, equine, poultry, swine, cleaning services, and more.

Our Commercial Ionizers:

These units are extremely heavy duty when compared to units manufactured in Japan. These units are also much more cost effective in terms of electrode and membrane replacement, i.e. electrode / membrane replacement cost for Japanese assembled unit is over $4,000.00usd and have the same life expectancy. 

Units must have pre-filtration equipment installed to ensure longevity and trouble free operation. It is recommended that source water is tested to ensure there is not a problem with chemical contamination such as nitrates. Total Hardness is the most common problem due to calcium and magnesium deposits that are naturally dissolved from the soil into water supplies. The Water Quality Association considers water to be “hard” when levels exceed one grain per gallon. To provide the public with a feel for the severity of the problem, the United States Geological Survey developed the following graphic showing Total Hardness levels throughout the US . The red areas on the map indicate levels from 181-250 ppm! pH and ORP may vary based on bottling source and materials used. We make no claims on final product in relation to pH or ORP.

Factors that determine the proper equipment for commercial applications include:

  • Reliability – Quality, long term trouble free operation, Properties of water produced, consistent pH and -ORP
  • Ease of Use – Ease of use: Total automation (As with any equipment, periodic monitoring is recommended)
  • Durability – Able to stand up to adverse conditions such as dust and high humidity
  • Cost effectiveness– Initial capital cost, operating costs, replacement parts cost
  • Warranty and Servicing – Backed by the manufacturer
  • Ability for user to replace components – Electrodes and membrane easily changed out by user

Commercial Unit Information & Specification Table

Model NameCommercial Hydracide UnitLC-500CE-1000LCE-2000LLife LC-11 X
Image
Ionized Water Production Type Continuous Flow Continuous Flow Continuous Flow Continuous Flow Automatic Flow
Electrical Specifications 110V or 220V | 50hz or 60hz | 30AMP Service 110V or 220V | 50hz or 60hz | 30AMP Service 110V or 220V | 50hz or 60hz | 30AMP Service 110V or 220V | 50hz or 60hz | 30AMP Service 110V or 220V | 50hz or 60hz | 30AMP Service
Dimensions (MM) 699W x 558D x 1100H 550W x 520D x 700H 699W x 558D x 1100H 699W x 558D x 1100H 546W x 381D x 292H
Unit Weight Approx 150 KG | 330 LBS Approx 60 KG | 132 LBS Approx 150 KG | 330 LBS Approx 150 KG | 330 LBS Approx 10 KG | 24 LBS
Flow Rate 4 Liters Per Minute | 1.05 Gallons Per Minute 300-350 Liters Per Hour | 70-80 Gallons Per Hour Up to 16 Liters Per Minute | 4 Gallons Per Minute Up to 32 Liters Per Minute | 8 Gallons Per Minute N/A
pH Levels* Acidic 2.3 - 2.7 pH Alkaline 8.0 - 10.0 pH Acidic 4.5 - 7.0 pH | Alkaline 7.5 - 10.0 pH Acidic 4.5 - 7.0 pH | Alkaline 7.5 - 10.0 pH Up to 11.0 pH
ORP Levels* +1000mV | CI 20mg/L - 60mg/L -250 to -600 -200 to -500 -200 to -500 Up to -900
Electrolyzed Enhancer 99% Pure Sodium Chloride N/A N/A N/A N/A
Electrode Materials Platinum Coated Titanium Platinum Coated Titanium Platinum Coated Titanium Platinum Coated Titanium Platinum Coated Titanium
Electrode Cleaning Cycle After Every Cleaning Through 3 Way Solenoid Valve After Every Cleaning Through 3 Way Solenoid Valve After Every Cleaning Through 3 Way Solenoid Valve After Every Cleaning Through 3 Way Solenoid Valve After Every Cleaning Through 3 Way Solenoid Valve
Number of Electrode Tank(s) 14 - Single Chamber N/A 1 1 N/A
Electrode Life 2500 Hours* 1000 - 4000 Hours Depending on Water Source 2500 Hours Average 2500 Hours Average 5000 Hours Average
Protection (Auto Shut-Off) Low/High Water Pressure or Overheating Low/High Water Pressure or Overheating Low/High Water Pressure or Overheating Low/High Water Pressure or Overheating Error Mode at PCB
Option 1 Built-in Bypass System Built-in Bypass System Built-in Bypass System Built-in Bypass System Built-in Bypass System
Option 2 Auto Float System (Auto Float Valve for Filling Tanks) Auto Float System (Auto Float Valve for Filling Tanks) Auto Float System (Auto Float Valve for Filling Tanks) Auto Float System (Auto Float Valve for Filling Tanks) Auto Float System (Auto Float Valve for Filling Tanks)
Environmental Temperature Limits 5 - 40° C | 41 - 104° F 5 - 40° C | 41 - 104° F 5 - 40° C | 41 - 104° F 5 - 40° C | 41 - 104° F 0 - 30° C | 32 - 86° F
Environmental Humidity Limits Less Than 85% Less Than 85% Less Than 85% Less Than 85% Less Than 85%
Water TDS Tolerance 150 - 500 150 - 500 150 - 500 150 - 500 20 - 150
Required Water Source Municipal, Well, or Salt Water Municipal, Well, or Salt Water Municipal, Well, or Salt Water Municipal, Well, or Salt Water Municipal or Well
Automated Proprietary Bypass System No Yes No No Automatic Water Way
Optional Mineral & Supplement Injection System Yes Yes Yes Yes No
Dual Amperage Settings Yes Yes Yes Yes Yes
Cleaning System Optional Feature Optional Feature Optional Feature Optional Feature Advanced RADC Cleaning
Warranty Call for Warranty Information Call for Warranty Information Call for Warranty Information Call for Warranty Information Call for Warranty Information
Price Call for Pricing Information Call for Pricing Information Call for Pricing Information Call for Pricing Information 1996

* Results may vary due to uniqueness of the source water.

** Price does not include optional items or shipping.